PIPE SIZES


The nominal internal diameters (I.D.) for common use low density poly pipe (LDPE) and class 12 PVC pressure pipe are often not true to their actual size.

Pipe

mm

I.D. mm

wall thickness

litres per metre

litres per minute at 0.8 metres per second

PVC

20

23.65

1.5/1.6

0.441

21.2

PVC

25

29.75

1.9

0.698

33.5

PVC

32

37.45

2.4

1.105

53

PVC

40

42.75

2.7/2.8

1.439

69

PVC

50

53.65

3.3/3.4

2.266

108.8

           

Poly (black)

19

19

 

0.284

13.6

Poly (black)

25

25.4

 

0.507

24.3


As can be seen…
25 mm class 12 PVC pipe has 38% more capacity than 25 mm poly pipe!
20 mm class 12 PVC pipe has 55% more capacity than 19 mm poly pipe!

NOTE: 25 mm (Blue Line) Poly I.D. varies with the pressure rating but the ‘middle ground’ is approx 20 mm.